ACETYLENE OXYGEN CO -- ACETYLENE -- 6830-00N054026
===================== Product Identification =====================
Product ID:ACETYLENE
MSDS Date:04/01/1984
FSC:6830
NIIN:00N054026
=== Responsible Party ===
Company Name:ACETYLENE OXYGEN CO
Box:430
City:HARLINGEN
State:TX
ZIP:79651
Country:US
Info Phone Num:512-423-4237
Emergency Phone Num:512-423-4237
CAGE:19196
=== Contractor Identification ===
Company Name:ACETYLENE OXYGEN CO
Box:City:HARLINGEN
State:TX
ZIP:79651
Country:US
Phone:512-423-4237
CAGE:19196
============= Composition/Information on Ingredients =============
Ingred Name:ACETYLENE
CAS:74-86-2
RTECS #:AO9600000
Other REC Limits:2500 PPM TWA(MFR)
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:EXPLO HAZ: OCCURS, A FLAME AS HIGH AS 15' COULD DEVELOP.
CYLINDERS EXPOSED TO EXTREME HEAT IN A FIRE SITUATION (ING 3)
RTECS #:9999999ZZ
Ingred Name:ING 2: MAY RUPTURE VIOLENTLY IF CYLINDERS ARE NOT KEPT
COOL. ACETYLENE IS LIGHTER THAN AIR & CAN ACCUMULATE IN (ING 4)
RTECS #:9999999ZZ
Ingred Name:ING 3: TOP OF ENCLOSED SPACES. POTENTIAL EXPLOSION HAZARD
FROM RE-IGNITION. AUTOIGNITION TEMP: 635F, 335 C.
RTECS #:9999999ZZ
Ingred Name:MATLS TO AVOID: ACETYLENE CAN REACT EXPLOSIVELY WHEN
IGNITED WITH OXGYEN, CHLORINE OR FLUORINE.
RTECS #:9999999ZZ
Ingred Name:DECOMP PRODS: INTO CARBON & HYDROGEN) GIVEN A SOURCE OF
IGNITION.
RTECS #:9999999ZZ
Ingred Name:SUPP DATA: SAFETY BULLETIN #4 "HANDLING ACETYLENE CYLINDERS
IN FIRE SITUATIONS".
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACETYLENE HAS BEEN USED AS AN
ANESTHETIC, BUT IT ACTS AS A SIMPLE ASPHYXIANT IF PRESENT IN
CONCENTRATIONS HIGH ENOUGH TO DEPRIVE LUNGS OF OXYGEN. EXPOSURE IN
OXYGEN-DEFICIENT ATMOSPHERES CAN CAUSE DIZ ZINESS, LOSS OF
CONSCIOUSNESS & DEATH; HOWEVER, LOWER FLAMMABLE LIMIT OF ACETYLENE
IN AIR IS REACHED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: BEFORE SUFFOCATION COULD OCCUR.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:ELIM ALL POSS SOURCES OF IGNIT. INHAL: REMOVE VICTIM TO FRESH
AIR. ASSISTED RESP & SUPPLEMENTAL OXYGEN SHOULD BE GIVEN IF THE
VICTIM IS NOT BRTHG. RESCUE PERS MAY REQ NIOSH/MSHA APPRVD SCBA.
EYES: FLU SH W/POTABLE WATER FOR A MINIMUN OF 15 MINS. SEEK ASIST
FROM MD. SKIN: FLUSH W/COPIOUS AMTS OF WATER. CALL MD. INGEST: CALL
MD IMMEDIATELY.
===================== Fire Fighting Measures =====================
Lower Limits:2.5%
Upper Limits:80%
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE AND WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
SHUT OFF SOURCE OF ACETYLENE, IF POSS. USE WATER SRRAY TO COOL FIRE
EXPOS CYL. SMALL FLAME (SUPP DATA)
Unusual Fire/Explosion Hazard:EXCESS HEAT/FIRE EXCEEDING
212F(TEMPERATURE OF BOILING WATER) WILL CAUSE FUSABLE SAFETY PLUGS
TO RELEASE ALLOWING ACETYLENE TO ESCAPE & IF IGNIT (ING 2)
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE IMMEDIATE AREA. ELIMINATE ANY
POSSIBLE IGNITION SOURCE & PROVIDE MAXIMUM EXPLOSION PROOF
VENTILATION. SHUT OFF SOURCE OF ACETYLENE IF POSSIBLE. ISOLATE ANY
LEAKING CYLINDER & CONTACT THE SUPP LIER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, WELL-VENT PLACE AWAY
FROM OPEN FLAMES & OTHER IGNITION SOURCES. DO NOT STORE W/IN 20
FEET OF OXYGEN OR OTHER OXIDZIERS.
Other Precautions:STORE CYLINDERS IN AN UPRIGHT POSITION. FOLLOW
GENERAL SAFETY PROCEDURES FOR HANDLING COMPRESSED GAS CYLINDERS
FOUND IN CGA PAMPHLET P-1.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: SUFFICIENT TO KEEP AREA BELOW 2% ACETYLENE
CONC. MECH: EXPLOS PROOF. NATURAL/MECH WHERE GAS IS PRESENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VAP DENS: 0.07314 LB/CU FT. SOLUB IN H*2O: 1.7 SCC/100CC H*2O @ 32F.
FIRE FIGHT PROC: MAY BE PUT OUT BUT IF LGE FLAME IS PRESENT, LET IT
BURN, PROVIDED PERS/BUILDING STRUCTURE IS NOT IN DANGER. IF FLA ME
IS EXTING & ACETYLENE CONTINUES TO ESCAPE AN EXPLOS RE-IGNIT COULD
OCCUR. FOLLOW INSTRUCTS FOUND IN CGA (ING 7)
================== Physical/Chemical Properties ==================
HCC:G2
Boiling Pt:B.P. Text:-103F,-75C
Vapor Pres:635 PSIG
Vapor Density:SUPP DATA
Spec Gravity:0.906 (AIR=1)
Solubility in Water:SUPP DATA
Appearance and Odor:COLORLESS GAS WITH DISTINCTIVE GARLIC-LIKE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACETYLENE CAN REACT W/COPPER, SILVER & MERCURY TO FORM ACELYHIDES;
THESE CMPDS COULD ACT AS AN IGNIT SOURCE.(ING 5)
Stability Condition to Avoid:DO NOT USE ACETYLENE AT PRESS IN EXCESS OF
15 PSIG(30 PSIA). IS STABLE BELOW 15 PSI/IN ACETONE SOLUTION IN ITS
CYLINDER.
Hazardous Decomposition Products:ACETYLENE UNDER PRESSURE CAN EVEN IN
THE ABSENCE OF AIR OR OXYGEN, BE MADE TO EXPLODE VIOLENTLY (I.E.
DECOMP (ING 6)
==================== Disposal Considerations ====================
Waste Disposal Methods:IF PRACTICAL, MOVE CYLINDER TO SAFE OUTSIDE AREA
AWAY FROM ANY SOURCE OF IGNITION. ALLOW THE CYLINDER TO DISCHARGE
SLOWLY INTO ATMOSPHERE & CONTACT THE SUPPLIER. DISPOSE OF IN
ACCORDANCE WITH LOCAL, S TATE & FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.